Product was successfully added to your shopping cart.
0item(s)

Vaša košarica je prazna

Industrijski Pretvorniki / Izolatorji

Set Descending Direction

   

Izdelki 1 do 10 od 23 skupaj

  1. 1
  2. 2
  3. 3
  1. (Ex) Izolator / Napajalnik DT1300

    Product features:

    • 0-20 mA / 4-20 mA / 0-10 V inputs
    • 0-20 mA / 4-20 mA / 0-10 V outputs
    • 17 VDC / 18 VDC transmitter supply
    • Non-linearity < 0.01%
    • Temperature-coefficient < 50 ppm / °C
    • 19-29 VDC supply voltage
    • TS-35 rail mounting, 12.5 mm width
    • 18 different types

  2. AC-Tokovni Pretvornik DT1600 I

    Product features:

    • 0-1 AAC / 0-5 AAC measurement ranges
    • Galvanic isolated inputs, CAT III
    • Average values / True RMS values
    • 0.2% accuracy class
    • 0-20 mA / 4-20 mA / 0-10 V outputs
    • 18-40 V AC/DC or 18-250 V AC/DC power supply
    • TS-35 rail mounting, 22.5 mm width
    • Full EN 60688 compliance

  3. AC-Napetostni Pretvornik DT1600 U

    Product features:

    • 0-125 VAC / 0-250 VAC / 0-450 VAC measurement ranges
    • Galvanic isolated input, CAT III
    • Average values / RMS values
    • 0.2 accuracy class
    • 0-20 mA / 4-20 mA / 0-10 V transmitter outputs
    • 18-40 V AC/DC / 180-250 V AC/DC power supply
    • TS-35 rail mounting, 22.5 mm width
    • Full EN 60688 compliance

  4. Končna Stikala DT1400

    Product features:

    • 0–20 mA / 4–20 mA / 0–10 V / 2–10 V / 0–5 V inputs
    • 2 / 4 x limit-relay outputs
    • Process indicator function
    • 5 digit LED display, 7,6 mm character height
    • Menu based configuration 
    • 0–20 mA / 4–20 mA isolated output
    • Transmitter supply
    • 18–40 V DC / 14–29 V AC power supply or 140–250 V AC / 180–250 V DC mains
    • TS-35 rail mounting, 45 mm width

  5. Enofazni Močnostni Pretvornik DEMS5010

    Product features:

    • Measuring of 12 different parameters:
      Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ
    • 0-125 VAC / 0-250 VAC / 0-450 VAC and
      0–5 AAC / 0–1 AAC galvanic isolated inputs
      CATIII measurement category
    • 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
    • RS232 / RS485 / ETHERNET communication interface
      MODBUS RTU slave / MODBUS TCP, HTTP protocol
    • 2 limit-relay outputs
    • Synchronous and time zone signal inputs
    • Pulse outputs
    • Configuration via USB port
    • 24 V AC/DC, 230 V AC/DC power supply
    • TS-35 rail mounting, 45 mm width

  6. Multifunkcijski Enofazni Močnostni Pretvornik PQRM5100 11

    Product features:

    • Measuring of 14 different single phase parameters:
      Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ, THD U, THD I
    • 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
      0-5 AAC / 0-1 AAC galvanic isolated current input
      CAT III measurement category
    • 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
    • MODBUS RTU/ASCII Slave communication
    • 2 x Pulse outputs / Limit-relay outputs
    • Configuration by PC via USB port
    • 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
    • TS-35 rail mounting, 22.5 mm width

  7. Trifazni Močnostni Pretvornik DEMS5030

    Product features:

    • More than 50 different measured parameters:
      Ueff, Ieff, f, P, S, Q, PF, φ, +EP, -EP, +EQ, -EQ (each phase)P, S, Q, PF, +EP, -EP, +EQ, -EQ (sum)UL1-L2, UL2-L3, UL1-L3, φL1-L2, φL1-L3 (between phase)P1/4h average value, P1/4h estimated average value, Plast 1/4h average value, t1/4h rest (demand)
    • 3 x 0-125 VAC / 0-250 VAC / 0-450 VAC,
      3 x 0-5 AAC / 0-1 AAC galvanic isolated inputs
      CATIII measurement category
    • 2 / 4 x 0-20 mA / 4-20 mA galvanic isolated outputs
    • RS232 / RS485 / ETHERNET interface
      MODBUS RTU slave / MODBUS TCP, HTTP protocol
    • 2 limit-relay outputs
    • Synchronous and time zone signal inputs
    • Pulse outputs
    • Configuration via USB port
    • 24 V AC/DC, 230 V AC/DC power supply
    • TS-35 rail mounting, 90 mm width

  8. Multifunkcijski Trifazni Močnostni Pretvornik PQRM5100 31

    Product features:

    • More then 50 different measured parameters
    • 3 x 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
      3 x 0-5 AAC / 0-1 AAC galvanic isolated current input
      CAT III category
    • Different measuring arrangement
    • 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
    • RS485 interface, MODBUS RTU/ASCII Slave protocol
    • 2 x Pulse outputs / Limit-relay outputs
    • Configuration by PC via USB port
    • 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
    • TS-35 rail mounting, 22.5 mm width

  9. Števec Pulzov DEMS5005

    Product features:

    • 8 x NAMUR / contact inputs
    • Counting of incoming pulses
    • Measuring the time between the incoming pulses 
    • RS232 / RS485 communication, MODBUS RTU protocol
    • Configuration via USB port
    • 24 V AC/DC, 230 V AC/DC power supply
    • TS-35 rail mounting, 45 mm width

    Type designation:
    DEMS5005 RS2 20-50 VDC / 19-35 VAC power supply, RS232 interface
    DEMS5005 RS2  PS 90-250 V AC/DC power supply, RS232 interface
    DEMS5005 RS4 20-50 VDC / 19-35 VAC power supply, RS485 interface
    DEMS5005 RS4  PS 90-250 V AC/DC power supply, RS485 interface

  10. Napajanje DT2014

    DT2014 features:

    • 4 x 22 VDC, 25 mA stabilized outputs
    • Outputs are galvanic isolated from each other
    • Overcurrent-protection with limiter characteristics
    • 190-250 VAC / 90-250 VDC power supply ranges
    • TS-35 rail mounting 12.5 mm width only