Prenosni instrumenti
Kimo prenosni instrumenti so namenjeni merjenju različnih veličin v industriji, okolju, laboratorijih. So enostavni za uporabo v izvedbah za osnovne in zahtevnejše uporabnike. Kompatibilni so z izmenljivimi sondami, poleg tega pa ponujajo še wireless komunikacijo, bluetooth in več (odvisno od vrste instrumenta).
Prenosni instrumenti
Product features:
- 0-125 VAC / 0-250 VAC / 0-450 VAC (rms max.) inputs
- 5 digit LED display, 14.2 mm character height
- 0.03% accuracy
- 0-20 mA / 4-20 mA, galvanic isolated output
- Min / max values detection
- 2 limit-relay outputs
- RS232 / RS485 communication, MODBUS RTU protocol
- 96 x 48 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- IP65 front side protection
Product features:
- Selectable and scalable input ranges:
-125 - +125 V / -2.5 - +2.5 V / -25 - +25 mA
- Selectable and scalable output renges:
0-22 mA / 0–10.5 V
- Configurable input and output parameters via USB port
- 3 way isolation
- Non-linearity: <0.01%
- Temperature-coefficient: 25 ppm / °C typ.
- 20-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 12.5 mm width
Type designation:
DT1102 V 20-50 VDC / 19-35 VAC power supply type
DT1102 V PS 90-250 V AC/DC power supply type
Product features:
- Selectable input/output ranges with front panel switches:
0-20 mA / 4-20 mA / 0-10 V / 2-10 V input
0-20 mA / 4-20 mA / 0-10 V / 2-10 V output
- 3 way isolation
- 20 V transmitter supply on the input for two wire transmitters
- Error: < 0.05%
- Temperature-coefficient: 25 ppm / °C typ.
- 19-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 12.5 mm width
- Square Root Characteristic
Type designation:
DT1102 ROOT 19–50 VDC / 19–35 VAC power supply type
DT1102 ROOT PS 90–250 V AC/DC power supply type
Product features:
- Selectable input/output ranges with front panel switches:
0-20 mA / 4-20 mA / 0-10 V / 2-10 V input
0-20 mA / 4-20 mA / 0-10 V / 2-10 V output
- 3 way isolation
- 20 V transmitter supply on the input for two wire transmitters
- Non-linearity: <0.01%
- Temperature-coefficient: 25 ppm / °C typ.
- 20-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 12.5 mm width
Type designation:
- DT1102 20-50 VDC / 19-35 VAC power supply type
- DT1102 PS 90-250 V AC/DC power supply type
Product features:
- Any output voltages between 6-24 VDC range
- 6 / 8 / 10 / 12 / 15 / 18 / 24 VDC nominal output
- Overcurrent-protection
- Overvoltage-protection
- 230 VAC power supply
- TS-35 rail mounting, 35 mm width
- 11 different types
Product features:
- Pt100 / Pt500 / Pt1000 inputs
- Resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- -200°C-800°C / 0-4000 ohm input ranges
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output ranges
- 0,03% accuracy
- Easy configuration via IR transmission
- 19-35 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
Product features:
- NAMUR / contact inputs
- Relay contact / transistor outputs
- 1 / 2 / 4 channel versions
- Line fault detection
- Switch selectable mode of operation
- 3 kHz transmission frequency (transistor output)
- 19-29 VDC supply voltage
- 12.5-22.5 mm széles, TS-35 sínre pattintható kivitelek
- 11 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- Non-linearity < 0,01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 9 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 17 VDC / 18 VDC transmitter supply
- Non-linearity < 0.01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 18 different types
Product features:
- 3 x 0-125 VAC / 0-250 VAC galvanic isolated voltage inputs
3 x 0-5 AAC / 0-1 AAC galvanic isolated current inputs
CATIII measuring category
- Neutral current measurement
- Harmonic analysis and THD measurement on voltages and currents
- Flicker measurement
- Voltage asymmetry measurement
- Network analysis according IEC61000-4-30
- Storage trends, evens and ADC samples on SD card
- Colour TFT graphics display
- RS485 / Ethernet interface
MODBUS RTU / ASCII slave / MODBUS TCP, HTTP, FTP, SMTP protocol
- 0-20 mA / 4-20 mA galvanic isolated transmitter outputs
- RS485 interface, MODBUS RTU/ASCII slave protocol
- Digital outputs (Pulse output, Limit output)
- Menu settings
- 19-35 VAC / 20-50 VDC vagy 90-250 V AC/DC power supply
- 96 x 96 mm panel instrument