Prenosni instrumenti
Kimo prenosni instrumenti so namenjeni merjenju različnih veličin v industriji, okolju, laboratorijih. So enostavni za uporabo v izvedbah za osnovne in zahtevnejše uporabnike. Kompatibilni so z izmenljivimi sondami, poleg tega pa ponujajo še wireless komunikacijo, bluetooth in več (odvisno od vrste instrumenta).
Prenosni instrumenti
DT4230 E features:
- RS232 / RS485 communication interface, Modbus RTU slave protocol
- 5 digit LED display, 14.2 mm character height, color: red
- 96 x 48 mm panel instrument
- 19-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
DT4232 features:
- RS232 / RS485 communication interface, Modbus RTU slave protocol
- 5 digit LED display, 20.3 mm character height
- 144 x 72 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
Product features:
- Display in engineering units
- 4 1/2 digit LCD, 20,5 mm character height
- 4–20 mA loop powered
- 2 isolated limit outputs
- Min / Max values detection
- 0,02% accuracy
- Intrinsically safe (zone 1, 2)
- Easy on-site configuration
- IP 65 front
IP 30 rear
DT4120 features:
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs, 2 / 3 / 4 wire measurement
- 5 digit red LED display, 14.2 mm character height
- 0.1°C resolution· 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (opcional)
- RS232 / RS485 communication, Modbus RTU protocol (opcional)
- 96 x 48 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
DT4122 features:
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs,
- 2 / 3 / 4 wire measurement
- 5 digit LED display, 20.3mm character height
- 0,1°C resolution
- 0-20 mA / 4-20 mA, galvanic isolated output (opcional)
- 2 limit relay output (opcional)
- RS232 / RS485 communication, Modbus RTU protocol (opcional)
- 144 x 72 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
DT9502 N features:
- Pt100 input, 3 / 4 wire measurement
- 0.1°C sensitivity, -200–600°C measuring range
- 4–20 mA loop powered
- 0.03% accuracy
- 2 isolated limit outputs
- Easy on-site configuration
- Calibrated sensor curve fitting
- Min / Max values detection
- Large size (20.5 mm) LCD display
- IP 65 front
IP 30 rear
DT9502 features:
- Pt100 input, 3 / 4 wire measurement
- Intrinsically safe (zone 1, 2)
- 0.1 °C sensitivity, -200–600°C measuring range
- 4-20 mA loop powered
- 0.03% accuracy
- 2 isolated limit outputs
- Easy on-site configuration
- Calibrated sensor curve fitting
- Min / Max values detection
- Large size (20.5 mm) display
- IP 65 front
IP 30 rear
Product features:
- 0-125 VAC / 0-250 VAC / 0-450 VAC (rms max.) inputs
- 5 digit LED display, 14.2 mm character height
- 0.03% accuracy
- 0-20 mA / 4-20 mA, galvanic isolated output
- Min / max values detection
- 2 limit-relay outputs
- RS232 / RS485 communication, MODBUS RTU protocol
- 96 x 48 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- IP65 front side protection
Product features:
- More than 50 different measured parameters on 3 phase network
- 0-125 VAC / 0-250 VAC / 0-450 VAC
0-5 AAC / 0-1 AAC galvanic isolated inputs
CATIII measuring category
- 4 x 16 character alphanumeric display
- 0–20 mA / 4–20 mA galvanic isolated outputs
- RS485 / RS232 / ETHERNET interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- Limit-relay outputs
- Pulse outputs
- Synchronous and time zone signal inputs
- 24 V AC/DC, 230 V AC/DC power supply
- 96 x 96 mm panel instrument
Product features:
- Resistance / potentiometer inputs
- 3 or 4 wire measurement
- 0-10000 ohm measurement ranges
- Two wire 4-20 mA transmitter
- 0.05% accuracy
- TS-35 rail mounting, 12.5 mm width