Prenosni instrumenti
Kimo prenosni instrumenti so namenjeni merjenju različnih veličin v industriji, okolju, laboratorijih. So enostavni za uporabo v izvedbah za osnovne in zahtevnejše uporabnike. Kompatibilni so z izmenljivimi sondami, poleg tega pa ponujajo še wireless komunikacijo, bluetooth in več (odvisno od vrste instrumenta).
Prenosni instrumenti
Product features:
- Measuring of the pressure of gases, vapours and liquids
- Measuring of relative / absolute pressure, vacuum
- 4-20 mA two-wire transmitter
- G 1/2"A / M20×1,5 / G 3/4"A process connections
- IP 65 protection
- Medium temperature: up to 90 °C
- 32 measurement ranges between 0 and 25 bar
- Intrinsically safe LCD display
Product features:
- Measuring of the pressure-differences of gases
- Measurement ranges between 0-5000 Pa
- LCD display
- Intrinsically safe
- 4-20 mA two-wire transmitter
- Medium temperature: up to 60°C
- IP 65 protection
Product features:
- Measuring of the pressure of gases
- Temperature of the medium: up to 40 °C
- 11 measurement ranges between 0 and 6 bar
- 4-20 mA two-wire remote transmitter
- Construction, push mountable on TS-32, TS-35 rails
- IP 20 protection
DT9500 N features:
- Pt100 input, 3 / 4 wire measurement
- -200-600°C measuring range
- 0.3°C accuracy
- 4-20 mA loop powered
- Easy on-site configuration
- Calibrated sensor curve fitting
- 2 isolated limit outputs
- Min / Max values detection
- 4 1/2 digit LCD, 20.5 mm character height
- IP 65 protection
DT9500 / DT9502 features:
- Pt100 input, 3 / 4 wire measurement
- -200-600°C measuring range
- 0.3°C accuracy
- 4-20 mA loop powered
- Easy on-site configuration
- Calibrated sensor curve fitting
- 2 isolated limit outputs
- Min / Max values detection
- 4 1/2 digit LCD, 20.5 mm character height
- Intrinsically safe (zone 1, 2)
- IP 65 protection
- IP 65 front protection (DT9502)
IP 30 rear protection
DT9000 N / DT9002 N features:
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min / Max values detection
- 2 isolated limit outputs
- 0.03% accuracy, ±20 ppm / °C
- Easy on-site configuration
- DT9000: IP 65
- DT9002: IP 65 front
IP 30 rear
Product features:
- 0-1 AAC / 0-5 AAC measurement ranges
- Galvanic isolated inputs, CAT III
- Average values / True RMS values
- 0.2% accuracy class
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 18-40 V AC/DC or 18-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
- Full EN 60688 compliance
Product features:
- 0-125 VAC / 0-250 VAC / 0-450 VAC measurement ranges
- Galvanic isolated input, CAT III
- Average values / RMS values
- 0.2 accuracy class
- 0-20 mA / 4-20 mA / 0-10 V transmitter outputs
- 18-40 V AC/DC / 180-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
- Full EN 60688 compliance
Product features:
- 0–20 mA / 4–20 mA / 0–10 V / 2–10 V / 0–5 V inputs
- 2 / 4 x limit-relay outputs
- Process indicator function
- 5 digit LED display, 7,6 mm character height
- Menu based configuration
- 0–20 mA / 4–20 mA isolated output
- Transmitter supply
- 18–40 V DC / 14–29 V AC power supply or 140–250 V AC / 180–250 V DC mains
- TS-35 rail mounting, 45 mm width
Product features:
- Measuring of 12 different parameters:
Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ
- 0-125 VAC / 0-250 VAC / 0-450 VAC and
0–5 AAC / 0–1 AAC galvanic isolated inputs
CATIII measurement category
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS232 / RS485 / ETHERNET communication interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- 2 limit-relay outputs
- Synchronous and time zone signal inputs
- Pulse outputs
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 45 mm width