Prenosni instrumenti
Kimo prenosni instrumenti so namenjeni merjenju različnih veličin v industriji, okolju, laboratorijih. So enostavni za uporabo v izvedbah za osnovne in zahtevnejše uporabnike. Kompatibilni so z izmenljivimi sondami, poleg tega pa ponujajo še wireless komunikacijo, bluetooth in več (odvisno od vrste instrumenta).
Prenosni instrumenti
Product features:
- Measuring of 14 different single phase parameters:
Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ, THD U, THD I
- 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
0-5 AAC / 0-1 AAC galvanic isolated current input
CAT III measurement category
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- MODBUS RTU/ASCII Slave communication
- 2 x Pulse outputs / Limit-relay outputs
- Configuration by PC via USB port
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
Product features:
- More than 50 different measured parameters:
Ueff, Ieff, f, P, S, Q, PF, φ, +EP, -EP, +EQ, -EQ (each phase)P, S, Q, PF, +EP, -EP, +EQ, -EQ (sum)UL1-L2, UL2-L3, UL1-L3, φL1-L2, φL1-L3 (between phase)P1/4h average value, P1/4h estimated average value, Plast 1/4h average value, t1/4h rest (demand)
- 3 x 0-125 VAC / 0-250 VAC / 0-450 VAC,
3 x 0-5 AAC / 0-1 AAC galvanic isolated inputs
CATIII measurement category
- 2 / 4 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS232 / RS485 / ETHERNET interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- 2 limit-relay outputs
- Synchronous and time zone signal inputs
- Pulse outputs
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 90 mm width
Product features:
- More then 50 different measured parameters
- 3 x 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
3 x 0-5 AAC / 0-1 AAC galvanic isolated current input
CAT III category
- Different measuring arrangement
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS485 interface, MODBUS RTU/ASCII Slave protocol
- 2 x Pulse outputs / Limit-relay outputs
- Configuration by PC via USB port
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
Product features:
- 8 x NAMUR / contact inputs
- Counting of incoming pulses
- Measuring the time between the incoming pulses
- RS232 / RS485 communication, MODBUS RTU protocol
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 45 mm width
Type designation:
DEMS5005 RS2 20-50 VDC / 19-35 VAC power supply, RS232 interface
DEMS5005 RS2 PS 90-250 V AC/DC power supply, RS232 interface
DEMS5005 RS4 20-50 VDC / 19-35 VAC power supply, RS485 interface
DEMS5005 RS4 PS 90-250 V AC/DC power supply, RS485 interface
DT2014 features:
- 4 x 22 VDC, 25 mA stabilized outputs
- Outputs are galvanic isolated from each other
- Overcurrent-protection with limiter characteristics
- 190-250 VAC / 90-250 VDC power supply ranges
- TS-35 rail mounting 12.5 mm width only
Product features:
- Transient voltage protection of the 4-20 mA current loop
- 3-stage protection
- 10 kA surge vawe (8 / 20 µs)
- 41 V max. Output noise voltage
- DIN rail mounting and IP 65 enclosure version
DT9000 / DT9002 features:
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min / Max values detection
- 2 isolated limit outputs
- 0.03 % accuracy, ±20 ppm / °C
- Intrinsically safe (zone 1, 2)
- Easy on-site configuration
- IP 65 protection
IP 30 rear protection (DT9002)
DT 6000 fetures:
- different type of unit version (UVI, W/m²)
- 3 1/2 digits LCD display with 12.7 mm character height
- handheld version
- quick sets
- 5 % accuracy
DT9000 N / DT9002 N features:
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- 2 isolated limit outputs
- Min / Max values detection
- 0.01% accuracy, ±20 ppm / °C
- Easy on-site configuration
- IP 65 front side
- IP 65 rear side (DT9000 N)
IP 30 rear side (DT9002 N)
DT4200 / DT420 E features:
- Display in engineering units
- 4 1/2 digit LCD display, 15 mm character height (DT4200)
3 1/2 digit LCD display, 15 mm character height (DT420 E)
- 4–20 mA loop-powered
- 2 isolated limit outputs
- Min / Max values detection
- 0.01% accurary, ±20 ppm / °C (DT4200)
0.02% accuracy, ±20 ppm / °C (DT420 E)
- Easy on site configuration
- IP 65 front side
IP 30 rear side