Anemometri - Merilniki pretoka zraka
Kimo Anemometri (merilniki hitrosti zraka), so enostavni za uporabo in natančni pri merjenju hitrosti zraka, pretok zraka, temperaturo (odvisno od modela). VT210 model se uporablja za kontrolo ventilacijskega sistema, VT110/VT115, pa ima žarilno nitko.
Anemometri
DT 6000 fetures:
- different type of unit version (UVI, W/m²)
- 3 1/2 digits LCD display with 12.7 mm character height
- handheld version
- quick sets
- 5 % accuracy
DT2014 features:
- 4 x 22 VDC, 25 mA stabilized outputs
- Outputs are galvanic isolated from each other
- Overcurrent-protection with limiter characteristics
- 190-250 VAC / 90-250 VDC power supply ranges
- TS-35 rail mounting 12.5 mm width only
Product features:
- 8 x NAMUR / contact inputs
- Counting of incoming pulses
- Measuring the time between the incoming pulses
- RS232 / RS485 communication, MODBUS RTU protocol
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 45 mm width
Type designation:
DEMS5005 RS2 20-50 VDC / 19-35 VAC power supply, RS232 interface
DEMS5005 RS2 PS 90-250 V AC/DC power supply, RS232 interface
DEMS5005 RS4 20-50 VDC / 19-35 VAC power supply, RS485 interface
DEMS5005 RS4 PS 90-250 V AC/DC power supply, RS485 interface
Product features:
- More then 50 different measured parameters
- 3 x 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
3 x 0-5 AAC / 0-1 AAC galvanic isolated current input
CAT III category
- Different measuring arrangement
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS485 interface, MODBUS RTU/ASCII Slave protocol
- 2 x Pulse outputs / Limit-relay outputs
- Configuration by PC via USB port
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
Product features:
- More than 50 different measured parameters:
Ueff, Ieff, f, P, S, Q, PF, φ, +EP, -EP, +EQ, -EQ (each phase)P, S, Q, PF, +EP, -EP, +EQ, -EQ (sum)UL1-L2, UL2-L3, UL1-L3, φL1-L2, φL1-L3 (between phase)P1/4h average value, P1/4h estimated average value, Plast 1/4h average value, t1/4h rest (demand)
- 3 x 0-125 VAC / 0-250 VAC / 0-450 VAC,
3 x 0-5 AAC / 0-1 AAC galvanic isolated inputs
CATIII measurement category
- 2 / 4 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS232 / RS485 / ETHERNET interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- 2 limit-relay outputs
- Synchronous and time zone signal inputs
- Pulse outputs
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 90 mm width
Product features:
- Measuring of 14 different single phase parameters:
Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ, THD U, THD I
- 0-125 VAC / 0-250 VAC non galvanic isolated voltage input
0-5 AAC / 0-1 AAC galvanic isolated current input
CAT III measurement category
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- MODBUS RTU/ASCII Slave communication
- 2 x Pulse outputs / Limit-relay outputs
- Configuration by PC via USB port
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
Product features:
- Measuring of 12 different parameters:
Ueff, Ieff, P, Q, S, +Ep, -Ep, +EQ, -EQ, PF, f, ϕ
- 0-125 VAC / 0-250 VAC / 0-450 VAC and
0–5 AAC / 0–1 AAC galvanic isolated inputs
CATIII measurement category
- 2 x 0-20 mA / 4-20 mA galvanic isolated outputs
- RS232 / RS485 / ETHERNET communication interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- 2 limit-relay outputs
- Synchronous and time zone signal inputs
- Pulse outputs
- Configuration via USB port
- 24 V AC/DC, 230 V AC/DC power supply
- TS-35 rail mounting, 45 mm width
Product features:
- 0–20 mA / 4–20 mA / 0–10 V / 2–10 V / 0–5 V inputs
- 2 / 4 x limit-relay outputs
- Process indicator function
- 5 digit LED display, 7,6 mm character height
- Menu based configuration
- 0–20 mA / 4–20 mA isolated output
- Transmitter supply
- 18–40 V DC / 14–29 V AC power supply or 140–250 V AC / 180–250 V DC mains
- TS-35 rail mounting, 45 mm width
Product features:
- 0-125 VAC / 0-250 VAC / 0-450 VAC measurement ranges
- Galvanic isolated input, CAT III
- Average values / RMS values
- 0.2 accuracy class
- 0-20 mA / 4-20 mA / 0-10 V transmitter outputs
- 18-40 V AC/DC / 180-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width
- Full EN 60688 compliance
Product features:
- 0-1 AAC / 0-5 AAC measurement ranges
- Galvanic isolated inputs, CAT III
- Average values / True RMS values
- 0.2% accuracy class
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 18-40 V AC/DC or 18-250 V AC/DC power supply
- TS-35 rail mounting, 22.5 mm width