Anemometri - Merilniki pretoka zraka
Kimo Anemometri (merilniki hitrosti zraka), so enostavni za uporabo in natančni pri merjenju hitrosti zraka, pretok zraka, temperaturo (odvisno od modela). VT210 model se uporablja za kontrolo ventilacijskega sistema, VT110/VT115, pa ima žarilno nitko.
Anemometri
DT4120 features:
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs, 2 / 3 / 4 wire measurement
- 5 digit red LED display, 14.2 mm character height
- 0.1°C resolution· 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (opcional)
- RS232 / RS485 communication, Modbus RTU protocol (opcional)
- 96 x 48 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
Product features:
- Selectable input/output ranges with front panel switches:
0-20 mA / 4-20 mA / 0-10 V / 2-10 V input
0-20 mA / 4-20 mA / 0-10 V / 2-10 V output
- 3 way isolation
- 20 V transmitter supply on the input for two wire transmitters
- Non-linearity: <0.01%
- Temperature-coefficient: 25 ppm / °C typ.
- 20-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 12.5 mm width
Type designation:
- DT1102 20-50 VDC / 19-35 VAC power supply type
- DT1102 PS 90-250 V AC/DC power supply type
Product features:
- Any output voltages between 6-24 VDC range
- 6 / 8 / 10 / 12 / 15 / 18 / 24 VDC nominal output
- Overcurrent-protection
- Overvoltage-protection
- 230 VAC power supply
- TS-35 rail mounting, 35 mm width
- 11 different types
Product features:
- Pt100 / Pt500 / Pt1000 inputs
- Resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- -200°C-800°C / 0-4000 ohm input ranges
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output ranges
- 0,03% accuracy
- Easy configuration via IR transmission
- 19-35 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
Product features:
- NAMUR / contact inputs
- Relay contact / transistor outputs
- 1 / 2 / 4 channel versions
- Line fault detection
- Switch selectable mode of operation
- 3 kHz transmission frequency (transistor output)
- 19-29 VDC supply voltage
- 12.5-22.5 mm széles, TS-35 sínre pattintható kivitelek
- 11 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- Non-linearity < 0,01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 9 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 17 VDC / 18 VDC transmitter supply
- Non-linearity < 0.01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 18 different types
Product features:
- 3 x 0-125 VAC / 0-250 VAC galvanic isolated voltage inputs
3 x 0-5 AAC / 0-1 AAC galvanic isolated current inputs
CATIII measuring category
- Neutral current measurement
- Harmonic analysis and THD measurement on voltages and currents
- Flicker measurement
- Voltage asymmetry measurement
- Network analysis according IEC61000-4-30
- Storage trends, evens and ADC samples on SD card
- Colour TFT graphics display
- RS485 / Ethernet interface
MODBUS RTU / ASCII slave / MODBUS TCP, HTTP, FTP, SMTP protocol
- 0-20 mA / 4-20 mA galvanic isolated transmitter outputs
- RS485 interface, MODBUS RTU/ASCII slave protocol
- Digital outputs (Pulse output, Limit output)
- Menu settings
- 19-35 VAC / 20-50 VDC vagy 90-250 V AC/DC power supply
- 96 x 96 mm panel instrument
Product features:
- More than 50 different measured parameters on 3 phase network
- 3 x 0-125 VAC / 0-250 VAC non galvanic isolated voltage inputs
3 x 0-5 AAC / 0-1 AAC galvanic isolated current inputs
CATIII measuring category
- Many measuring arrangement: network with or without neutral, 1/2/3 power input(s)
- Graphics display
- 0-20 / 4-20 mA galvanic isolated transmitter output
- RS485 interface, MODBUS RTU/ASCII slave protocol
- Pulse output, Limit outputs
- Settings menu
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- 96 x 96 mm panel instrument
Product features:
- More than 50 different measured parameters on 3 phase network
- 0-125 VAC / 0-250 VAC / 0-450 VAC
0-5 AAC / 0-1 AAC galvanic isolated inputs
CATIII measuring category
- 4 x 16 character alphanumeric display
- 0–20 mA / 4–20 mA galvanic isolated outputs
- RS485 / RS232 / ETHERNET interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- Limit-relay outputs
- Pulse outputs
- Synchronous and time zone signal inputs
- 24 V AC/DC, 230 V AC/DC power supply
- 96 x 96 mm panel instrument