Manometri / Micromanometri
Kimo manometri lahko merijo več parametrov hkrati, ki se prikazujejo izmenično. Micromanometer MP 210 lahko prikazuje do 6 parametrov naenkrat.
MP 210 in AMI 310 imata več vhodov za sonde kot so npr. pitot cevi, Pt100, sonde za merjenje kvalitete zraka, obratov, hitrost zraka, itd.
Manometri / Micromanometri
DT4120 features:
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs, 2 / 3 / 4 wire measurement
- 5 digit red LED display, 14.2 mm character height
- 0.1°C resolution· 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (opcional)
- RS232 / RS485 communication, Modbus RTU protocol (opcional)
- 96 x 48 mm panel instrument
- 18-40 V AC/DC or 180-250 V AC/DC power supply
- Protection IP65 (front), IP30 (rear)
Product features:
- Selectable input/output ranges with front panel switches:
0-20 mA / 4-20 mA / 0-10 V / 2-10 V input
0-20 mA / 4-20 mA / 0-10 V / 2-10 V output
- 3 way isolation
- 20 V transmitter supply on the input for two wire transmitters
- Non-linearity: <0.01%
- Temperature-coefficient: 25 ppm / °C typ.
- 20-50 VDC / 19-35 VAC or 90-250 V AC/DC power supply
- TS-35 rail mounting, 12.5 mm width
Type designation:
- DT1102 20-50 VDC / 19-35 VAC power supply type
- DT1102 PS 90-250 V AC/DC power supply type
Product features:
- Any output voltages between 6-24 VDC range
- 6 / 8 / 10 / 12 / 15 / 18 / 24 VDC nominal output
- Overcurrent-protection
- Overvoltage-protection
- 230 VAC power supply
- TS-35 rail mounting, 35 mm width
- 11 different types
Product features:
- Pt100 / Pt500 / Pt1000 inputs
- Resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- -200°C-800°C / 0-4000 ohm input ranges
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output ranges
- 0,03% accuracy
- Easy configuration via IR transmission
- 19-35 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
Product features:
- NAMUR / contact inputs
- Relay contact / transistor outputs
- 1 / 2 / 4 channel versions
- Line fault detection
- Switch selectable mode of operation
- 3 kHz transmission frequency (transistor output)
- 19-29 VDC supply voltage
- 12.5-22.5 mm széles, TS-35 sínre pattintható kivitelek
- 11 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- Non-linearity < 0,01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 9 different types
Product features:
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 17 VDC / 18 VDC transmitter supply
- Non-linearity < 0.01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 18 different types
Product features:
- 3 x 0-125 VAC / 0-250 VAC galvanic isolated voltage inputs
3 x 0-5 AAC / 0-1 AAC galvanic isolated current inputs
CATIII measuring category
- Neutral current measurement
- Harmonic analysis and THD measurement on voltages and currents
- Flicker measurement
- Voltage asymmetry measurement
- Network analysis according IEC61000-4-30
- Storage trends, evens and ADC samples on SD card
- Colour TFT graphics display
- RS485 / Ethernet interface
MODBUS RTU / ASCII slave / MODBUS TCP, HTTP, FTP, SMTP protocol
- 0-20 mA / 4-20 mA galvanic isolated transmitter outputs
- RS485 interface, MODBUS RTU/ASCII slave protocol
- Digital outputs (Pulse output, Limit output)
- Menu settings
- 19-35 VAC / 20-50 VDC vagy 90-250 V AC/DC power supply
- 96 x 96 mm panel instrument
Product features:
- More than 50 different measured parameters on 3 phase network
- 3 x 0-125 VAC / 0-250 VAC non galvanic isolated voltage inputs
3 x 0-5 AAC / 0-1 AAC galvanic isolated current inputs
CATIII measuring category
- Many measuring arrangement: network with or without neutral, 1/2/3 power input(s)
- Graphics display
- 0-20 / 4-20 mA galvanic isolated transmitter output
- RS485 interface, MODBUS RTU/ASCII slave protocol
- Pulse output, Limit outputs
- Settings menu
- 19-35 VAC / 20-50 VDC or 90-250 V AC/DC power supply
- 96 x 96 mm panel instrument
Product features:
- More than 50 different measured parameters on 3 phase network
- 0-125 VAC / 0-250 VAC / 0-450 VAC
0-5 AAC / 0-1 AAC galvanic isolated inputs
CATIII measuring category
- 4 x 16 character alphanumeric display
- 0–20 mA / 4–20 mA galvanic isolated outputs
- RS485 / RS232 / ETHERNET interface
MODBUS RTU slave / MODBUS TCP, HTTP protocol
- Limit-relay outputs
- Pulse outputs
- Synchronous and time zone signal inputs
- 24 V AC/DC, 230 V AC/DC power supply
- 96 x 96 mm panel instrument